TRANSIENT CHARACTERISTICS RDN 25/09Note: (A) Nominal current at continuous operating voltages = 10 - 75 pA. (B) Maximum current at continuous operating voltages = 300 pA (C) Average po Continous DC volts max (v)31 Maximum energy 10X100 psJ (Joules)3.2 Peak current @8X20 ps Ip (A MAX)500 Voltage @ 1m ADC Vn (Vn +/10%)40 Typical clamping voltage Vc (V)73 @8X20 ps test pulse Ip (A)5 Typical CAP.@1 KHz C (pF)3000 QTY per box Nos :200TRANSIENT CHARACTERISTICS RDN 25/14Continous DC volts max (v)31 Maximum energy 10X100 psJ (Joules)7.2 Peak current @8X20 ps Ip (A MAX)1000 Voltage @ 1m ADC Vn (Vn +/10%)40 Typical clamping voltage Vc (V)115 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)6100 QTY per box Nos :100TRANSIENT CHARACTERISTICS RDN 30/09Continous DC volts max (v)38 Maximum energy 10X100 psJ (Joules)4.3 Peak current @8X20 ps Ip (A MAX)500 Voltage @ 1m ADC Vn (Vn +/10%)47 Typical clamping voltage Vc (V)85 @8X20 ps test pulse Ip (A)5 Typical CAP.@1 KHz C (pF)2500 QTY per box Nos :200TRANSIENT CHARACTERISTICS RDN 30/14Continous DC volts max (v)38 Maximum energy 10X100 psJ (Joules)8.8 Peak current @8X20 ps Ip (A MAX)1000 Voltage @ 1m ADC Vn (Vn +/10%)47 Typical clamping voltage Vc (V)120 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)5000 QTY per box Nos :100
-
TRANSIENT CHARACTERISTICS RDN 40/09Continous DC volts max (v)56 Maximum energy 10X100 psJ (Joules)6.2 Peak current @8X20 ps Ip (A MAX)500 Voltage @ 1m ADC Vn (Vn +/10%)68 Typical clamping voltage Vc (V)120 @8X20 ps test pulse Ip (A)5 Typical CAP.@1 KHz C (pF)1800 QTY per box Nos :200<TRANSIENT CHARACTERISTICS RDN 40/14Continous DC volts max (v)56 Maximum energy 10X100 psJ (Joules)13 Peak current @8X20 ps Ip (A MAX)1000 Voltage @ 1m ADC Vn (Vn +/10%)68 Typical clamping voltage Vc (V)123 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)3500 QTY per box Nos :100TRANSIENT CHARACTERISTICS RDN 50/09Continous DC volts max (v)66 Maximum energy 10X100 psJ (Joules)7.5 Peak current @8X20 ps Ip (A MAX)500 Voltage @ 1m ADC Vn (Vn +/10%)82 Typical clamping voltage Vc (V)130 @8X20 ps test pulse Ip (A)5 Typical CAP.@1 KHz C (pF)1000 QTY per box Nos :200TRANSIENT CHARACTERISTICS RDN 50/14Continous DC volts max (v)66 Maximum energy 10X100 psJ (Joules)15 Peak current @8X20 ps Ip (A MAX)4500 Voltage @ 1m ADC Vn (Vn +/10%)82 Typical clamping voltage Vc (V)152 @8X20 ps test pulse Ip (A)50 Typical CAP.@1 KHz C (pF)1600 QTY per box Nos :100
-
TRANSIENT CHARACTERISTICS RDN 60/09Continous DC volts max (v)80 Maximum energy 10X100 psJ (Joules)9.5 Peak current @8X20 ps Ip (A MAX)500 Voltage @ 1m ADC Vn (Vn +/10%)1000 Typical clamping voltage Vc (V)160 @8X20 ps test pulse Ip (A)5 Typical CAP.@1 KHz C (pF)900 QTY per box Nos :200TRANSIENT CHARACTERISTICS RDN 60/14Continous DC volts max (v)80 Maximum energy 10X100 psJ (Joules)20 Peak current @8X20 ps Ip (A MAX)1000 Voltage @ 1m ADC Vn (Vn +/10%)100 Typical clamping voltage Vc (V)175 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)3000 QTY per box Nos :100TRANSIENT CHARACTERISTICS RDN 60/20Continous DC volts max (v)80 Maximum energy 10X100 psJ (Joules)30 Peak current @8X20 ps Ip (A MAX)2500 Voltage @ 1m ADC Vn (Vn +/10%)100 Typical clamping voltage Vc (V)165 @8X20 ps test pulse Ip (A)25 Typical CAP.@1 KHz C (pF)5000 QTY per box Nos :50TRANSIENT CHARACTERISTICS RDN 95/09Continous DC volts max (v)125 Maximum energy 10X100 psJ (Joules)8 Peak current @8X20 ps Ip (A MAX)2000 Voltage @ 1m ADC Vn (Vn +/10%)150 Typical clamping voltage Vc (V)250 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)600 QTY per box Nos :200
-
TRANSIENT CHARACTERISTICS RDN 94/14Continous DC volts max (v)125 Maximum energy 10X100 psJ (Joules)22 Peak current @8X20 ps Ip (A MAX)4500 Voltage @ 1m ADC Vn (Vn +/10%)150 Typical clamping voltage Vc (V)260 @8X20 ps test pulse Ip (A)50 Typical CAP.@1 KHz C (pF)800 QTY per box Nos :100TRANSIENT CHARACTERISTICS RDN 110/09Continous DC volts max (v)150 Maximum energy 10X100 psJ (Joules)18 Peak current @8X20 ps Ip (A MAX)2000 Voltage @ 1m ADC Vn (Vn +/10%)180 Typical clamping voltage Vc (V)295 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)550 QTY per box Nos :200TRANSIENT CHARACTERISTICS RDN 130/09Continous DC volts max (v)175 Maximum energy 10X100 psJ (Joules)15 Peak current @8X20 ps Ip (A MAX)2000 Voltage @ 1m ADC Vn (Vn +/10%)200 Typical clamping voltage Vc (V)350 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)450 QTY per box Nos :200TRANSIENT CHARACTERISTICS RDN 130/14Continous DC volts max (v)175 Maximum energy 10X100 psJ (Joules)30 Peak current @8X20 ps Ip (A MAX)4500 Voltage @ 1m ADC Vn (Vn +/10%)200 Typical clamping voltage Vc (V)340 @8X20 ps test pulse Ip (A)50 Typical CAP.@1 KHz C (pF)100 QTY per box Nos :100
-
TRANSIENT CHARACTERISTICS RDN 130/20Continous DC volts max (v)175 Maximum energy 10X100 psJ (Joules)60 Peak current @8X20 ps Ip (A MAX)6500 Voltage @ 1m ADC Vn (Vn +/10%)200 Typical clamping voltage Vc (V)340 @8X20 ps test pulse Ip (A)100 Typical CAP.@1 KHz C (pF)2000 QTY per box Nos :50TRANSIENT CHARACTERISTICS RDN 150/09Continous DC volts max (v)200 Maximum energy 10X100 psJ (Joules)21 Peak current @8X20 ps Ip (A MAX)2000 Voltage @ 1m ADC Vn (Vn +/10%)240 Typical clamping voltage Vc (V)405 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)350 QTY per box Nos :200TRANSIENT CHARACTERISTICS RDN 150/14Continous DC volts max (v)200 Maximum energy 10X100 psJ (Joules)45 Peak current @8X20 ps Ip (A MAX)4500 Voltage @ 1m ADC Vn (Vn +/10%)240 Typical clamping voltage Vc (V)395 @8X20 ps test pulse Ip (A)50 Typical CAP.@1 KHz C (pF)850 QTY per box Nos :100TRANSIENT CHARACTERISTICS RDN 150/20Continous DC volts max (v)200 Maximum energy 10X100 psJ (Joules)70 Peak current @8X20 ps Ip (A MAX)6500 Voltage @ 1m ADC Vn (Vn +/10%)240 Typical clamping voltage Vc (V)370 @8X20 ps test pulse Ip (A)100 Typical CAP.@1 KHz C (pF)1800 QTY per box Nos :50
-
TRANSIENT CHARACTERISTICS RDN 175/09Continous DC volts max (v)225 Maximum energy 10X100 psJ (Joules)23 Peak current @8X20 ps Ip (A MAX)2000 Voltage @ 1m ADC Vn (Vn +/10%)285 Typical clamping voltage Vc (V)455 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)300 QTY per box Nos :200TRANSIENT CHARACTERISTICS RDN 240/07Continous DC volts max (v)330 Maximum energy 10X100 psJ (Joules)21 Peak current @8X20 ps Ip (A MAX)1200 Voltage @ 1m ADC Vn (Vn +/10%)390 Typical clamping voltage Vc (V)650 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)110 QTY per box Nos :200TRANSIENT CHARACTERISTICS RDN 240/09Continous DC volts max (v)330 Maximum energy 10X100 psJ (Joules)25 Peak current @8X20 ps Ip (A MAX)2000 Voltage @ 1m ADC Vn (Vn +/10%)390 Typical clamping voltage Vc (V)650 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)180 QTY per box Nos :150TRANSIENT CHARACTERISTICS RDN 240/14Continous DC volts max (v)330 Maximum energy 10X100 psJ (Joules)70 Peak current @8X20 ps Ip (A MAX)4500 Voltage @ 1m ADC Vn (Vn +/10%)390 Typical clamping voltage Vc (V)650 @8X20 ps test pulse Ip (A)50 Typical CAP.@1 KHz C (pF)475 QTY per box Nos :75
-
TRANSIENT CHARACTERISTICS RDN 240/20Continous DC volts max (v)330 Maximum energy 10X100 psJ (Joules)130 Peak current @8X20 ps Ip (A MAX)6500 Voltage @ 1m ADC Vn (Vn +/10%)390 Typical clamping voltage Vc (V)620 @8X20 ps test pulse Ip (A)100 Typical CAP.@1 KHz C (pF)1100 QTY per box Nos :50TRANSIENT CHARACTERISTICS RDN 275/07Continous DC volts max (v)370 Maximum energy 10X100 psJ (Joules)23 Peak current @8X20 ps Ip (A MAX)1200 Voltage @ 1m ADC Vn (Vn +/10%)430 Typical clamping voltage Vc (V)710 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)100 QTY per box Nos :200TRANSIENT CHARACTERISTICS RDN 275/09Continous DC volts max (v)370 Maximum energy 10X100 psJ (Joules)40 Peak current @8X20 ps Ip (A MAX)2000 Voltage @ 1m ADC Vn (Vn +/10%)430 Typical clamping voltage Vc (V)715 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)150 QTY per box Nos :150TRANSIENT CHARACTERISTICS RDN 275/14Continous DC volts max (v)370 Maximum energy 10X100 psJ (Joules)75 Peak current @8X20 ps Ip (A MAX)4500 Voltage @ 1m ADC Vn (Vn +/10%)430 Typical clamping voltage Vc (V)715 @8X20 ps test pulse Ip (A)50 Typical CAP.@1 KHz C (pF)430 QTY per box Nos :57
-
TRANSIENT CHARACTERISTICS RDN 275/20Continous DC volts max (v)370 Maximum energy 10X100 psJ (Joules)140 Peak current @8X20 ps Ip (A MAX)6500 Voltage @ 1m ADC Vn (Vn +/10%)430 Typical clamping voltage Vc (V)690 @8X20 ps test pulse Ip (A)100 Typical CAP.@1 KHz C (pF)1000 QTY per box Nos :25TRANSIENT CHARACTERISTICS RDN 300/07Continous DC volts max (v)405 Maximum energy 10X100 psJ (Joules)45 Peak current @8X20 ps Ip (A MAX)1200 Voltage @ 1m ADC Vn (Vn +/10%)470 Typical clamping voltage Vc (V)750 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)100 QTY per box Nos :200TRANSIENT CHARACTERISTICS RDN 320/09Continous DC volts max (v)415 Maximum energy 10X100 psJ (Joules)60 Peak current @8X20 ps Ip (A MAX)2000 Voltage @ 1m ADC Vn (Vn +/10%)500 Typical clamping voltage Vc (V)605 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)140 QTY per box Nos :150TRANSIENT CHARACTERISTICS RDN 320/14Continous DC volts max (v)415 Maximum energy 10X100 psJ (Joules)09 Peak current @8X20 ps Ip (A MAX)4500 Voltage @ 1m ADC Vn (Vn +/10%)500 Typical clamping voltage Vc (V)850 @8X20 ps test pulse Ip (A)50 Typical CAP.@1 KHz C (pF)325 QTY per box Nos :75
-
TRANSIENT CHARACTERISTICS RDN 320/20Continous DC volts max (v)415 Maximum energy 10X100 psJ (Joules)150 Peak current @8X20 ps Ip (A MAX)6500 Voltage @ 1m ADC Vn (Vn +/10%)500 Typical clamping voltage Vc (V)820 @8X20 ps test pulse Ip (A)100 Typical CAP.@1 KHz C (pF)730 QTY per box Nos :25TRANSIENT CHARACTERISTICS RDN 440/14Continous DC volts max (v)630 Maximum energy 10X100 psJ (Joules)95 Peak current @8X20 ps Ip (A MAX)4500 Voltage @ 1m ADC Vn (Vn +/10%)720 Typical clamping voltage Vc (V)1250 @8X20 ps test pulse Ip (A)50 Typical CAP.@1 KHz C (pF)300 QTY per box Nos :50TRANSIENT CHARACTERISTICS RDN 440/20Continous DC volts max (v)630 Maximum energy 10X100 psJ (Joules)170 Peak current @8X20 ps Ip (A MAX)6500 Voltage @ 1m ADC Vn (Vn +/10%)720 Typical clamping voltage Vc (V)1175 @8X20 ps test pulse Ip (A)100 Typical CAP.@1 KHz C (pF)700 QTY per box Nos :25TRANSIENT CHARACTERISTICS RDN 510/09Continous DC volts max (v)675 Maximum energy 10X100 psJ (Joules)75 Peak current @8X20 ps Ip (A MAX)200 Voltage @ 1m ADC Vn (Vn +/10%)820 Typical clamping voltage Vc (V)800 @8X20 ps test pulse Ip (A)10 Typical CAP.@1 KHz C (pF)100 QTY per box Nos :100
-
TRANSIENT CHARACTERISTICS RDN 510/14Continous DC volts max (v)675 Maximum energy 10X100 psJ (Joules)110 Peak current @8X20 ps Ip (A MAX) 4500 Voltage @ 1m ADC Vn (Vn +/10%)820 Typical clamping voltage Vc (V)1350 @8X20 ps test pulse Ip (A)50 Typical CAP.@1 KHz C (pF)250 QTY per box Nos :50TRANSIENT CHARACTERISTICS RDN 510/20Continous DC volts max (v)675 Maximum energy 10X100 psJ (Joules)190 Peak current @8X20 ps Ip (A MAX)6500 Voltage @ 1m ADC Vn (Vn +/10%)820 Typical clamping voltage Vc (V)1300 @8X20 ps test pulse Ip (A)100 Typical CAP.@1 KHz C (pF)650 QTY per box Nos :25TRANSIENT CHARACTERISTICS RDN 560/20Continous DC volts max (v)740 Maximum energy 10X100 psJ (Joules)210 Peak current @8X20 ps Ip (A MAX)6500 Voltage @ 1m ADC Vn (Vn +/10%)880 Typical clamping voltage Vc (V)1350 @8X20 ps test pulse Ip (A)100 Typical CAP.@1 KHz C (pF)500 QTY per box Nos :25TRANSIENT CHARACTERISTICS RDN 660/20Continous DC volts max (v)870 Maximum energy 10X100 psJ (Joules)250 Peak current @8X20 ps Ip (A MAX)6500 Voltage @ 1m ADC Vn (Vn +/10%)1040 Typical clamping voltage Vc (V)1400 @8X20 ps test pulse Ip (A)100 Typical CAP.@1 KHz C (pF)450 QTY per box Nos :25
-
TRANSIENT CHARACTERISTICS RDN 680/14Continous DC volts max (v)795 Maximum energy 10X100 psJ (Joules)150 Peak current @8X20 ps Ip (A MAX)4500 Voltage @ 1m ADC Vn (Vn +/10%)1100 Typical clamping voltage Vc (V)1500 @8X20 ps test pulse Ip (A)50 Typical CAP.@1 KHz C (pF)225 QTY per box Nos :50Continuous DC (Vm dc) Volts : 175 Transient Energy 10X1000ps (J)Joules : 70 Transient Peak Current 8X20 ps (lo)Amps : 6500 Characteristics Varistor Voltage @1 mA DC Test Current Vn = 10% Volts : 200 Characteristics TYpical Clamping Voltage at 100A @8X20 ps Test Pulse Vc Volts : 360 Typical Capacitance @ 1KHZ (C)pF : 2000SPECIFICATIONS CONTINUOUS AC RMS VOLTS RDPContinuous DC (Vm dc) Volts : 330 Transient Energy 10X1000ps (J)Joules : 130 Transient Peak Current 8X20 ps (lo)Amps : 6500 Characteristics Varistor Voltage @1 mA DC Test Current Vn = 10% Volts : 390 Characteristics TYpical Clamping Voltage at 100A @8X20 ps Test Pulse Vc Volts : 675 Typical Capacitance @ 1KHZ (C)pF : 1100SPECIFICATIONS CONTINUOUS AC RMS VOLTS RDPContinuous DC (Vm dc) Volts : 369 Transient Energy 10X1000ps (J)Joules : 140 Transient Peak Current 8X20 ps (lo)Amps : 6500 Characteristics Varistor Voltage @1 mA DC Test Current Vn = 10% Volts : 430 Characteristics TYpical Clamping Voltage at 100A @8X20 ps Test Pulse Vc Volts : 740 Typical Capacitance @ 1KHZ (C)pF : 1000
-
SPECIFICATIONS CONTINUOUS AC RMS VOLTS RDPContinuous DC (Vm dc) Volts : 415 Transient Energy 10X1000ps (J)Joules : 150 Transient Peak Current 8X20 ps (lo)Amps : 6500 Characteristics Varistor Voltage @1 mA DC Test Current Vn = 10% Volts : 550 Characteristics TYpical Clamping Voltage at 100A @8X20 ps Test Pulse Vc Volts : 850 Typical Capacitance @ 1KHZ (C)pF : 730SPECIFICATIONS CONTINUOUS AC RMS VOLTS RDPContinuous DC (Vm dc) Volts : 640 Transient Energy 10X1000ps (J)Joules : 180 Transient Peak Current 8X20 ps (lo)Amps : 6500 Characteristics Varistor Voltage @1 mA DC Test Current Vn = 10% Volts : 750 Characteristics TYpical Clamping Voltage at 100A @8X20 ps Test Pulse Vc Volts : 1280 Typical Capacitance @ 1KHZ (C)pF : 700SPECIFICATIONS CONTINUOUS AC RMS VOLTS RDPContinuous DC (Vm dc) Volts : 730 Transient Energy 10X1000ps (J)Joules : 220 Transient Peak Current 8X20 ps (lo)Amps : 6500 Characteristics Varistor Voltage @1 mA DC Test Current Vn = 10% Volts : 910 Characteristics TYpical Clamping Voltage at 100A @8X20 ps Test Pulse Vc Volts : 1560 Typical Capacitance @ 1KHZ (C)pF : 450SPECIFICATIONS CONTINUOUS AC RMS VOLTS RDPContinuous DC (Vm dc) Volts : 850 Transient Energy 10X1000ps (J)Joules : 250 Transient Peak Current 8X20 ps (lo)Amps : 6500 Characteristics Varistor Voltage @1 mA DC Test Current Vn = 10% Volts : 1050 Characteristics TYpical Clamping Voltage at 100A @8X20 ps Test Pulse Vc Volts : 1820 Typical Capacitance @ 1KHZ (C)pF : 400
IC ' S • Connectors • Capacitors • Relays • Diodes/Rectifiers • Fans • Mosfet • Resistors • SCR/Diacs/Triacs • Switches
• Transistors • IGBT Modules • Varistors • LED/Displays • Potentiomentrrs • Solid State Relays
• Transistors • IGBT Modules • Varistors • LED/Displays • Potentiomentrrs • Solid State Relays
Surya Enterprises
89/3, Geetanjali Bhaudaji 'X' , Road No. 9,
Matunga, Mumbai - 400 019.
Tel: +91-22-3810106 / +91-22-4023364
Mobile: 9820335517 • Telefax: 91-22-66314445
E-mail ID: [email protected]
89/3, Geetanjali Bhaudaji 'X' , Road No. 9,
Matunga, Mumbai - 400 019.
Tel: +91-22-3810106 / +91-22-4023364
Mobile: 9820335517 • Telefax: 91-22-66314445
E-mail ID: [email protected]
- Home
- |
- About Us
- |
- Products
- |
- Get Quote
- |
- Contact Us
All Rights Reserved. Copyright © Surya Enterprises
Powered By : iThink Infotech Pvt. Ltd.